Checking the Slope of Temperature Increase Rate in DSC Tester
In DSC-time page of DSC tester move two cursers (Start and End) in the temperature increasing rate section to the linear section of graph. In the bottom section of graph you see data for two cursors. time and temperature data for that two cursor is indicated. you can easily calculate the slope of the line….
Installation and Connection to DTCOM Software
Calibration offset value. Be noted after set of proper value don’t forget to “ENTER”. Unless the value will not be saved.
Calibration of DSC OIT Tester from AHP PLASTIK MAKINA
1- Frist be sure that the driver of machine is installed in the computer [How to install communication driver] 2- Install DTCOM software [How to install DTCOM software]. 3- Open DTCOM software and connect to proper virtual COM port that is installed in No.1 4- Now you have connection to address 1 and 2 as…
How to install and run AHP ROTO software
Software installation 1- Along with the machine you get a flash disk including software of AHP ROTO 2- In the My Installer there is a folder named “Volume” 3- In this folder just right click “Set up.exe” and select “run as administrator” 4- Don’t change default root for installation and continue till the end 5-…
How to Use DSC OIT Tester software
OIT measurement After installation of driver: And installation of the software: Main panel of software has 4 pages: First of all set the parameters for OIT test as below (got to “parameters Tab”): For OIT measurement you need to set two main parameters of “Setpoint(degC)” and “Rate(degC/min)”. For example for PE OIT measurement temperature is…
DSC ( OIT ) Tester Software Installation
Before installation of software you need to install communication driver as below guide. Then you have two folders in the software disk. Don’t forget that flash disk of software is not only the software it is also hardware lock for software and you need to keep it for replacement from company side in even in…
Calibration of Hydrostatic Pressure Tester (Pressure and Temperature)
Calibration offset value. Be noted after set of proper value don’t forget to “ENTER”.
Tensile Testing Software Installation
Tensile test software has installation folder as below: 1- Click on My Installer folder 2- Click on folder Volume 3- Right click on Setup.Exe and “run as administrator” 4- Then install the software in the default root. Please don’t change the installation default root. 5- Next you need to install the driver for communication and…